100% Pass Your H19-338 Exam Dumps at First Attempt with Pass4guide [Q69-Q88]

Share

100% Pass Your H19-338 Exam Dumps at First Attempt with Pass4guide

Penetration testers simulate H19-338 exam PDF

NEW QUESTION 69
Which statement about the ROW technology for OceanStor V5 is true?

  • A. ROW-based snapshots do not have extra data copies, and therefore the performance is better.
  • B. One of the advantages of ROW is that it does not easily generate data fragments
  • C. Block snapshots use the ROW technology

Answer: A

 

NEW QUESTION 70
How many controllers can be concurrently accessed by a single SSD in OceanStor Dorado V6 high-end storage?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 71
Which storage systems support gateway-free active-active configuration? (Multiple choice)

  • A. NetApp A300
  • B. Huawei OceanStor V5
  • C. EMC PowerMax
  • D. EMC Unity

Answer: B,C

 

NEW QUESTION 72
Which are the convergence technologies that OceanStor V5 converged storage support? (Multiple choice)

  • A. Convergence of flash storage: interconnection between different types, models, and generations.
  • B. Active-active convergencE: HyperMetro for SAN and NAS, RPO=0, RTO=0.
  • C. Cloud convergence: hybrid cloud interoperability, along with public cloud migration, backup, and DR.
  • D. Convergence of SAN and NAS: HyperMetro for SAN and NAS, multi-service integration.
  • E. Convergence of storage resource pools: resource pooling and interruption free heterogeneous migration.

Answer: A,B,D,E

 

NEW QUESTION 73
Which statements about HyperMetro (Active-Active) supports by Dorado are correct? (Multiple Choice)

  • A. Gateway-free
  • B. Online upgrade from a single DC to dual-DC HyperMetro
  • C. Online upgrade from the HyperMetro solution to the 3DC solution

Answer: A,B,C

 

NEW QUESTION 74
OceanStor 100D provides inline deduplication.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 75
Which statements about the SmartTier feature for FS are NOT true? (Multiple choice)

  • A. The migration unit of the FS SmartTier feature is Extent.
  • B. The media in the FS SmartTier feature are divided into three layers SSD, SAS, and NL-SAS.
  • C. The SmartTier features of the FS can define the migration rate.
  • D. The scope of the SmartTier feature of the FS is a single pool.

Answer: A,B,C,D

 

NEW QUESTION 76
Among the Dorado series storage systems, which back-end technology provides the shortest theoretical latency?

  • A. PCIe
  • B. SAS
  • C. NVMe

Answer: C

 

NEW QUESTION 77
Which of the following statements are correct about the performance test of Dorado V6 mid-range product models on a Fiber Channel network? (Multiple choice)

  • A. The performance when native multipathing software is used is similar to that when UltraPath is used.
  • B. The test performance of a single LUN on Dorado V6 can reach over 80% of the system performance.
  • C. Dorado V6 delivers similar performance when using RAID 5, RAID 6, and RAID-TP.

Answer: B,C

 

NEW QUESTION 78
Which of the following are storage protocols for host connection in SAN? (Multiple choice)

  • A. FC
  • B. iSCSI
  • C. SAS
  • D. NoF (NVMe over Fabric)

Answer: A,B,D

 

NEW QUESTION 79
Which of the following statement is incorrect about the Active-Active architecture of Dorado V6?

  • A. ALUA must be configured when the operating system's native multipathing software is used.
  • B. LUNs are not owned by any controller.
  • C. The logical paths of the host are Active-Active.
  • D. Load is balanced among controllers.

Answer: A

 

NEW QUESTION 80
Which technologies can reduce write I/O latency in long-distance active-active scenarios? (Multiple choice)

  • A. FastWrite
  • B. RDMA
  • C. Gateway-free design
  • D. Optimistic lock

Answer: A,C,D

 

NEW QUESTION 81
OceanStor 100D uses NVDIMMs as cache, which can prevent data loss during power failure.

  • A. No
  • B. Yes

Answer: B

 

NEW QUESTION 82
Before the PoC test for Dorado V3, which of the following statements about Dorado V3 test is true (same with Dorado V6)?

  • A. All of the above.
  • B. We need to collect the host type and version.
  • C. We need to collect the application type of example, database, VDf, etc.
  • D. We should try to collect the I/O block size from application. Then we can select a suitable I/O block siza when we create LUNs.

Answer: A

 

NEW QUESTION 83
Which is the scale-out networking protocol that OceanStor Dorado V6 supports?

  • A. PCIe
  • B. RoCE
  • C. IB
  • D. FC

Answer: B

 

NEW QUESTION 84
In OceanStor Dorado V6, one LUN is enough for testing close-to-maximum performance.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 85
Which networking architectures are provided by Huawei geo-redundant 3D DR solution? (Multiple choice)

  • A. Parallel networking
  • B. Serial networking
  • C. Ring networking

Answer: A,B,C

 

NEW QUESTION 86
The HyperMetro architecture of OceanStor Dorado V6 belongs to which of the following categories?

  • A. Active-active gateway-free
  • B. Active-active gateway
  • C. Active-passive gateway
  • D. Active-passive gateway-free

Answer: A

 

NEW QUESTION 87
A technology evenly distributes workloads to each disk, thereby preventing continuous hot data access from causing a premature failure of some disks. This technology is called

  • A. Hot cache
  • B. Anti-wear leveling
  • C. Wear leveling

Answer: C

 

NEW QUESTION 88
......

All H19-338 Dumps and Training Courses: https://www.pass4guide.com/H19-338-exam-guide-torrent.html

Help candidates to study and pass the HCPP-Storage Exams hassle-free: https://drive.google.com/open?id=1p_dsr5RAOl1W8WaNDqlabaumKFZB8hEJ