NEW QUESTION 10
In a 4-node MetroCluster cluster, both clusters are alerting that the connection to an ATTO bridge is lost.
Which three components should be verified to determine what is causing this problem? (Choose three.)
- A. the dark fiber cables between sites
- B. the ATTO bridge
- C. the fiber cable that is connecting the ATTO bridge to the switch
- D. the SFPs in the storage controllers
- E. the SFPs that are connecting the ATTO bridge to the switch
Answer: B,C,E
NEW QUESTION 11
A customer's FAS8200 node1 went down an hour ago after a WAFL inconsistency error. All data is being served from partner node2, but the storage failover show command output is not showing a node1 as "Waiting for giveback".
What is the corrective action for this situation?
- A. From the LOADER prompt, run the wafliron command on the system's root aggregate.
- B. Boot the system and run the WAFL_check command on the inconsistent data aggregate.
- C. Re-create the root aggregate on node1.
- D. Boot the system and run the wafliron command on the inconsistent data aggregate.
Answer: C
NEW QUESTION 12
Click the exhibit button.
A customer notifies you that Active IQ is showing a warning that a broadcast domain in their environment has been configured with ports from multiple VLANs.
Referring to the exhibit, which two statements are correct? (Choose two.)
- A. A VLAN tag cannot be assigned to the e0M port, so the configuration is acceptable.
- B. You should move the e0M ports to a Broadcast Domain that is dedicated to only management traffic.
- C. You should configure e0M so that is tagged on VLAN 40.
- D. You should change the LIF service policy to net-intercluster to prevent the LIFs from failing over to the e0M ports.
Answer: C,D
NEW QUESTION 13
Click the exhibit button.
A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?
- A. There are operation types that are not listed in the output.
- B. The problem is due to a difference in operation size.
- C. Perfstat should be used to explain the behavior.
- D. A case with NetApp should be raised to find the root cause.
Answer: B
NEW QUESTION 14
In a 4-node cluster, nodes 1 and 2 are an HA pair, and nodes 3 and 4 are an HA pair. The following error appears in the log.
12/15/2018 15:48:47 node-2CRITICALclam.node.ooq: Node (name=node- 2, ID= 1001) is out of "CLAM quorum" (reason =quorum update).
In this scenario, which two statements are correct? (Choose two.)
- A. Node 2 takes over node 1.
- B. All LUNs are offline in the cluster.
- C. All LUNs are online in the cluster.
- D. Node 1 takes over node 2.
Answer: B,D
NEW QUESTION 15
Two weeks ago, your customer experienced a data outage, which caused their MCC to switch over. When the power was restored, they found that 14 disks over three RAID groups had failed, which caused two data aggregates to lose their mirror plexes.
In this situation, before you perform a switchback, which three actions should be taken? (Choose three.)
- A. Initiate the aggregate healing phases.
- B. Adjust bridge configuration for the replaced disks.
- C. Assign all disks on the remote site to the surviving nodes.
- D. Delete the failed plexes.
- E. Mirror the unmirrored aggregates
Answer: A,B,E
NEW QUESTION 16
Your customer added a new DS2246 shelf to an existing stack on their FAS8060A system. The customer then noticed that the new shelf's disks appear with the shelf serial number instead of the shelf ID in the sysconfig -r command output.
What is the reason for this problem?
- A. The ACP is cabled incorrectly.
- B. There is failed IOM module in the new shelf.
- C. The new shelf has the same ID as another shelf.
- D. The SAS is cabled incorrectly.
Answer: D
NEW QUESTION 17
Click the exhibit button.
You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)
- A. FC switch SwB1
- B. ISL cables
- C. FC switch SwA2
- D. storage bridges BrB1
- E. FC switch SwA1
Answer: A,B,E
NEW QUESTION 18
A customer reports that OnCommand Performance Manager shows that the workload on node-02 in a 4-node cluster has increased to a level that is higher than the threshold. The customer wants to avoid this issue becoming a performance problem.
Which two actions would result in achieving this goal? (Choose two.)
- A. Use the volume move command to move one or more volumes to another aggregate that is owned by another node that is less utilized.
- B. Use the storage aggregate scrub command to verify the parity on the busy aggregates.
- C. Physically move the shelf to another node that is less utilized.
- D. Use the storage aggregate relocation command to offload an aggregate to its partner.
Answer: A,C
NEW QUESTION 19
You have a 2-node ONTAP Select HA deployment. In this scenario, which application manages the quorum, if one node fails?
- A. vCenter Server
- B. ONTAP Deploy VM
- C. ONTAP Mediator
- D. Tiebreaker
Answer: B
NEW QUESTION 20
A customer has created an interface group (igroup) named a0a, a VLAN named a0a-2500, and a data LIF associated with the VLAN interface that has been assigned an IP of 10.254.10.100. The customer is able to ping 10.254.10.100 from a Windows client without any issues, but data traffic is not working.
In this scenario, what is the solution to the problem?
- A. Allow data traffic by using LIF firewall policies.
- B. Correct the MTU mismatch between the broadcast domain configuration and the upstream network switches.
- C. Configure an appropriate service policy for the data LIF.
- D. Disable flow control on the a0a interface.
Answer: A
NEW QUESTION 21
Click the exhibit button.
Your customer added a new DS4246 shelf to their FAS system. They created an aggregate on the new shelf.
Two weeks later, they log in to Active IQ and discover the Medium Impact error shown below.
"Both SAS connections from one controller go to the same shelf."
Referring to the exhibit, which statement is correct?
- A. A faulty cable is causing the problem.
- B. A faulty IOM is causing the problem.
- C. You are unable to obtain a "Cable Visualization" overview from Active IQ.
- D. You can correct this problem without downtime on the FAS system.
Answer: D
NEW QUESTION 22
A customer reports that copying data over iSCSI attached LUNs is taking significantly longer than usual. The customer asks you to help to identify the root cause of this problem.
Which two perfstat sections would you use to accomplish this task? (Choose two.)
- A. stats volume
- B. lun stats -vserver
- C. statit
- D. stats lun
Answer: B,C
NEW QUESTION 23
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?
- A. Configure the SVM for FCP and try scanning again.
- B. Set up LUN mapping and try scanning again.
- C. Set up Selective LUN Mapping (SLM) and try scanning again.
- D. Configure the ONTAP nodes for HA and try scanning again.
Answer: C
NEW QUESTION 24
Click the exhibit button.
Referring to the exhibit, which change is required to enable the CIFS Autolocation function for the Users share?
- A. Change the CIFS share's Symlink Properties parameter to symlinks.
- B. Modify the CIFS server's option to enable SMB multichannel.
- C. Edit the CIFS share's properties to remove the changenotify property.
- D. Re-create the LIFs to allow both CIFS and NFS protocols.
Answer: A
NEW QUESTION 25
An administrator wants to keep an automatic daily up-to-date copy of a volume at a disaster recovery location.
What should the administrator do to achieve this goal?
- A. Configure a SyncMirror relationship to the remote location.
- B. Perform an NDMP dump to the remote location.
- C. Configure a SnapMirror relationship to the remote location.
- D. Perform a volume relocation to the remote location.
Answer: C
NEW QUESTION 26
Click the exhibit button.
You execute a few commands and many fail, as shown in the exhibit.
What could cause the error?
- A. The aggregates were manually brought offline.
- B. The bcomd user space process on cluster1-02 failed.
- C. The cluster-02 node is down.
- D. The mgwd user space process on cluster1-02 failed.
Answer: C
NEW QUESTION 27
You want to determine which SMB versions that a CIFS server can use when communicating with external servers.
Which two CIFS server settings should be reviewed to accomplish this task? (Choose two.)
- A. smb1-enabled
- B. smb2-enabled-for-dc-conections
- C. smb2-enabled
- D. smb1-enabled-for-dc-connections
Answer: A,B
NEW QUESTION 28
Click the exhibit button.
A customer reports that their system recently began logging an error.
Referring to the exhibit, which two statements are correct? (Choose two.)
- A. A user is attempting to restart the ntpd daemon.
- B. The spmd application failed to restart the ntpd daemon.
- C. The bcomd application is responsible for monitoring the observed behavior.
- D. The ntpd daemon is responsible for time services.
Answer: A,D
NEW QUESTION 29
You migrated from a FAS3250 system to a new A200 system. After the migration, you notice that data compaction fails to be enabled on the migrated volumes.
In this scenario, which statement is correct?
- A. You need to schedule background deduplication on all volumes.
- B. Data compaction is not supported on the A200 system.
- C. You need a license to have full efficiency on AFF systems.
- D. The volumes are thick-provisioned.
Answer: D
NEW QUESTION 30
A customer reports that a takeover has been disabled on an HA pair.
What would be a cause for this to happen?
- A. The HA interconnect is not functioning properly.
- B. The cluster network is not functioning properly.
- C. The interface for the hardware assist has become unavailable.
- D. There is a disk running too hot.
Answer: A
NEW QUESTION 31
......
NetApp NS0-592 Exam Certification Details:
| Exam Registration | PEARSON VUE |
| Duration | 120 minutes |
| Passing Score | 62% |
| Recommended Training | ONTAP Troubleshooting (ILT) |
| Number of Questions | 60 |
| Exam Code | NS0-592 NCSE ONTAP |
| Sample Questions | NetApp NS0-592 Sample Questions |
| Exam Name | Support Engineer ONTAP Specialist |
| Exam Price | $150 USD |
Get ready to pass the NS0-592 Exam right now using our Network Appliance NCSE Exam Package: https://www.pass4guide.com/NS0-592-exam-guide-torrent.html